A Universal DetectorDetects all semi- and non-volatile analytes in your sample, including those transparent to other detectors.
Fully Gradient CompatibleHandles any combination of volatile mobile phases and gradients for powerful separations and minimized run times.
Higher Sensitivity than RI and other ELSDs on the marketThe ELSD-LTII is 10 - 100X more sensitive than RI detectors for all samples and under all mobile phase conditions.
Detects all analytes, including semi-volatiles, at near-ambient evaporation temperaturesAbsolute temperature range (Ambient - 80°C)
Commonly used working range (Ambient - 40°C)
Semi-volatile analytes and compounds that thermally decompose are easily missed with competing detectors.
Accepts a wide range of mobile phase flowsThe ELSD-LTII displays excellent signal/noise characteristics over solvent flows from 100µL/min. to 4.0 mL/min.
Single-Mode operationLow temperature operation without accessories, separate operating modes. Most analyses are done using a common set of conditions (Gain 5; Temp 40°C; P 350kPa).
Time program air/nitrogen shutoffA time program method may be used to shut off the inlet gas, ending the problem of wasted gas after work is done.
Unique nebulizer/drift tube design offers protection from 'fouling'The nebulizer and drift tube are separated by a glass chamber which protects the evaporation and detection stages from particle buildup. In competing detectors, such buildup contributes to background noise that cannot be solved without maintenance.
Stack other detectors on top of the ELSD-LTIIThe ELSD-LTII fits perfectly into the modular design of Shimadzu Prominence HPLC hardware. Dimensions: W260 x D550mm x H450
  1. Elsd Troubleshooting
  2. Alltech Elsd 2000 Detector User Manual Download

Elsd Troubleshooting

Alltech elsd 2000 detector user manual pdf

Alltech Elsd 2000 Detector User Manual Download

Alltech Elsd 2000 Detector User Manual

Alltech has more than 15 years of experience engineering and manufacturing Evaporative Light Scattering Detectors. Our global network of dedicated application chemists and technical support professionals provide you with the comprehensive service and support you need. Let us show you how an Alltech ELSD can improve your analysis! Alltech ELSD. ELSD 2000 Control Software Manual for further details. Refer to Section 6.2, Replacement Parts, for part numbers if replacement parts are needed. INTRODUCTION 1.1 ABOUT THE ELSD 2000 The Alltech ELSD 2000 (Evaporative Light Scattering Detector) is designed for use with High Performance Liquid Chromatography (HPLC) systems to analyze any compound. Alltech has more than 15 years of experience engineering and manufacturing Evaporative Light Scattering Detectors. Our global network of dedicated application chemists and technical support professionals provide you with the comprehensive service and support you need. Let us show you how an Alltech ELSD can improve your analysis! Alltech ELSD. ELSD 2000: The Grace Davison / Alltech ELSD 2000 (Evaporative Light Scattering Detector) is designed for use with High Performance Liquid Chromatography (HPLC) systems to analyze any compound that has sufficiently lower volatility than the mobile phase.